 300W Single Output with PFC Function
Features :
HRPG-300
series
Universal AC input / Full range Built-in active PFC function, PF>0.95 High efficiency up to 89% (typ.) Withstand 300VAC surge input for 5 seconds Protections: Short circuit / Overload / Over voltage / Over temperature Built-in constant current limiting circuit 1U low profile 41mm Built-in cooling fan ON-OFF control With DC OK signal output Built-in remote ON-OFF control Standby 5V@0.3A Built-in remote sense function No load power consumption<0.5W 5 years warranty
SPECIFICATION
MODEL DC VOLTAGE RATED CURRENT CURRENT RANGE RATED POWER OUTPUT VOLTAGE ADJ. RANGE LINE REGULATION LOAD REGULATION SETUP, RISE TIME HOLD UP TIME (Typ.) HRPG-300-3.3 HRPG-300-5 3.3V 60A 0 ~ 60A 198W 5V 60A 0 ~ 60A 300W 90mVp-p 4.3 ~ 5.8V 2.0% 0.5% 1.0% HRPG-300-7.5 HRPG-300-12 HRPG-300-15 HRPG-300-24 HRPG-300-36 HRPG-300-48 7.5V 40A 0 ~ 40A 300W 100mVp-p 6.8 ~ 9V 2.0% 0.5% 1.0% 12V 27A 0 ~ 27A 324W 120mVp-p 10.2 ~ 13.8V 1.0% 0.3% 0.5% 15V 22A 0 ~ 22A 330W 150mVp-p 13.5 ~ 18V 1.0% 0.3% 0.5% 24V 14A 0 ~ 14A 336W 150mVp-p 21.6 ~ 28.8V 1.0% 0.2% 0.5% 36V 9A 0 ~ 9A 324W 250mVp-p 28.8 ~ 39.6V 1.0% 0.2% 0.5% 48V 7A 0 ~ 7A 336W 250mVp-p 40.8 ~ 55.2V 1.0% 0.2% 0.5%
RIPPLE & NOISE (max.) Note.2 80mVp-p 2.8 ~ 3.8V VOLTAGE TOLERANCE Note.3 2.5% 0.5% 1.0% 16ms/230VAC
1000ms, 50ms/230VAC
2500ms, 50ms/115VAC at full load
16ms/115VAC at full load 120 ~ 370VDC PF>0.99/115VAC at full load 86% 88% 88% 87% 88% 89%
VOLTAGE RANGE Note.5 85 ~ 264VAC FREQUENCY RANGE 47 ~ 63Hz POWER FACTOR (Typ.) INPUT EFFICIENCY (Typ.) AC CURRENT (Typ.) INRUSH CURRENT (Typ.) LEAKAGE CURRENT OVERLOAD OVER VOLTAGE PF>0.95/230VAC 80% 5A/115VAC 35A/115VAC
82% 2.5A/230VAC 70A/230VAC
<1.2mA / 240VAC 105 ~ 135% rated output power Protection type : Constant current limiting, recovers automatically after fault condition is removed 6 ~ 7V 9.4 ~ 10.9V 14.4 ~ 16.8V 18.8 ~ 21.8V 30 ~ 34.8V 3.96 ~ 4.62V Protection type : Shut down o/p voltage, re-power on to recover 90 5 5 (TSW1: detect on heatsink of power transistor) for 3.3V,5V,7.5V ; 95 5 for others (TSW2: detect on heatsink of power diod e) 100
41.4 ~ 48.6V
57.6 ~ 67.2V
PROTECTION
OVER TEMPERATURE 5V STANDBY FUNCTION DC OK SIGNAL REMOTE CONTROL FAN CONTROL (Typ.) WORKING TEMP.
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down 5VSB : 5V@0.3A ; tolerance 5%, ripple : 50mVp-p(max.) PSU turns on : 3.3 ~ 5.6V ; PSU turns off : 0 ~ 1V RC+ / RC-: 4 ~ 10V or open = power on ; 0 ~ 0.8V or short = power off Load 35 15% or RTH2 -30 ~ +70 50 Fan on (Refer to output load derating curve)
20 ~ 90% RH non-condensing WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY -40 ~ +85 , 10 ~ 95% RH TEMP. COEFFICIENT 0.03%/ (0 ~ 50 ) VIBRATION 10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes SAFETY STANDARDS WITHSTAND VOLTAGE SAFETY & EMC
(Note 4)
UL60950-1, TUV EN60950-1 approved I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC / 70% RH
ISOLATION RESISTANCE HARMONIC CURRENT EMS IMMUNITY MTBF
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B
Compliance to EN61000-3-2,-3 Compliance to EN61000-4-2,3,4,5,6,8,11, ENV50204, EN55024, EN61000-6-2, heavy industry level, criteria A 176K hrs min. MIL-HDBK-217F (25 ) 199*105*41mm (L*W*H) 0.95Kg;15pcs/15.3Kg/0.69CUFT
OTHERS
DIMENSION PACKING
NOTE
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. 5. Derating may be needed under low input voltages. Please check the derating curve for more details.
File Name:HRPG-300-SPEC 2009-11-09
300W Single Output with PFC Function
Mechanical Specification
HRPG-300
Case No.980A
18 12.5
series
Unit:mm
4-M4 L=6 168.5
R2 .25
168.5 199
12.25
1.5 HOLE IN CHASSIS
4.5
18
168.5 120
12.25 42.5
1
11
Terminal Pin No. Assignment
Pin No. 1 2 3 Assignment AC/L AC/N FG Assignment Pin No. DC OUTPUT -V 4,5 6,7 DC OUTPUT +V
2 3 4 5 6 7 LED CN100 SVR
4-M4 L=5
4-M4 L=6
Block Diagram
AUX POWER EMI FILTER ACTIVE INRUSH CURRENT LIMITING RECTIFIERS & PFC O.T.P. FG PFC CONTROL PWM CONTROL POWER SWITCHING O.L.P.
RECTIFIERS & FILTER RECTIFIERS & FILTER DETECTION CIRCUIT O.V.P. REMOTE CONTROL
I/P
Derating Curve
Output Derating VS Input Voltage
Ta = 25
100
100 90
80
80 70
60
LOAD (%)
50 40
LOAD(%)
60 50 40
20
-30
0
10
20
30
40
50
60
70
(HORIZONTAL)
85
100
125
135
155
AMBIENT TEMPERATURE ( )
INPUT VOLTAGE (V) 60Hz
File Name:HRPG-300-SPEC 2009-11-09
12.5 18 41
Pin No. Assignment AUX 1 AUXG 2 DC-OK 3 RC4 GND 5 RC+ 6 +S 7 -S 8
Mating Housing
Terminal
167.5 167.5 12.25 12.25
HRS DF11-8DS or equivalent
HRS DF11-**SC or equivalent
17max.
15
Connector Pin No. Assignment (CN100) : HRS DF11-8DP-2DS or equivalent
75 105 125
9.2
FAN
Air flow direction
17
28
fosc : 70KHz
AUX AUXG +S +V -V -S DC-OK
RC+ RC-
264
300W Single Output with PFC Function
Function Description of CN100
HRPG-300
series
Pin No. Function Description Auxiliary voltage output, 4.6~5.25V, reference to pin 2(AUXG). The maximum load current is 0.3A. This output has the built-in oring 1 AUX diodes and is not controlled by the "remote ON/OFF control". 2 3 4 5 6 7 8 AUXG DC-OK RCGND RC+ +S -S Auxiliary voltage output ground. The signal return is isolated from the output terminals (+V & -V). DC-OK signal is a TTL level signal, referenced to pin5(DC-OK GND). High when PSU turns on. Remote control ground. This pin connects to the negative terminal(-V). Return for DC-OK signal output. Turns the output on and off by electrical or dry contact between pin 4 (RC-), Short: Power OFF, Open: Power ON. Positive sensing. The +S signal should be connected to the positive terminal of the load. The +S and -S leads should be twisted in pair to minimize noise pick-up effect. The maximum line drop compensation is 0.5V. Negative sensing. The -S signal should be connected to the negative terminal of the load. The -S and +S leads should be twisted in pair to minimize noise pick-up effect. The maximum line drop compensation is 0.5V.
Function Manual
1.Remote Sense The remote sensing compensates voltage drop on the load wiring up to 0.5V.
CN100 1 AUX DC-OK GND RC+ +S -S 7 8
1
2
3
4
5
6
7 CN100
2 AUXG RC-
17 28
-S (Pin8)
LOAD +
+S (Pin7)
Sense lines should be twisted in pairs
Fig 1.1
2.DC-OK Signal DC-OK signal is a TTL level signal. High when PSU turns on.
Between DC-OK(pin6) and GND(pin4) 3.3 ~ 5.6V 0 ~ 1V Output Status ON OFF
CN100
1 2 3 4 5 6 7 CN100
1
AUX DC-OK GND RC+
+S -S
7 8
2 AUXG RC-
17 28
Fig 2.1
File Name:HRPG-300-SPEC 2009-11-09
300W Single Output with PFC Function
HRPG-300
series
3.Remote Control The PSU can be turned ON/OFF by using the "Remote ON/OFF" function
Between RC+(pin3) and RC-(pin5) SW ON (Short) SW OFF (Open) Output Status OFF ON
CN100 1 AUX DC-OK GND RC+ +S -S 7 8
1
2
3
4
5
6
7 CN100
2 AUXG RC-
17 28
SW Fig 3.1
File Name:HRPG-300-SPEC 2009-11-09


▲Up To Search▲   

 
Price & Availability of HRPG-300-33

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X